(812) 309-78-59
(495) 223-46-76
ASTM D4844-03
Standard Guide for Air Monitoring at Waste Management Facilities for Worker Protection
8 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
13.030.40 Installations. Including street cleaning equipment, waste containers, incineration and compaction equipment, equipment for dumping of refuse, landfill sites, etc. / Установки и оборудование для удаления и обработки отходов. Включая оборудование для очистки улиц, контейнеры для отходов, оборудование для сжигания и прессования, оборудование для сброса отходов, места свалок и т.д.13.040.40 Stationary source emissions / Выбросы стационарных источников
Сборник (ASTM):
11.04 Waste Management / Управление отходами
Тематика:
Waste Management
Описание
Значение и использование

The techniques of air monitoring are many and varied. This guide is intended to describe the standard approaches that are used in designing an air monitoring program to protect waste management site workers.

When entering a remedial action site to initiate an investigation or a cleanup operation, operating personnel may be faced with the extreme hazards of fire, explosion, and acute or chronic health hazards. A thorough safety and health program, including a site-specific safety and health plan, must be in place to direct worker activity. Details for such plans can be found in the OSHA Interim Final Rule for Hazardous Waste Operations and Emergency Response and Refs (1, 2).7 Air monitoring is an integral part of such a program. This guide describes equipment and sampling procedures which can be used to evaluate the airborne hazard potential so as to gain and maintain control over the situation at the site.

Upon obtaining readings at the site, a decision must be made as to whether conditions are under control or not. That decision will depend on the nature of the contaminants (toxicity, reactivity, volatility, etc.), the extent (area affected, number of workers, etc.) of the problem and the level of worker protection available. Since all such parameters will be site specific, the necessary decision-making is beyond the range of this guide.

This guide does not include monitoring sites containing radioactive materials, nor does it cover general safety aspects, such as access to emergency equipment or medical support of emergency needs. These items should be covered in a safety and health plan.

It is recommended that this guide be used in conjunction with Guide D 4687.

Область применения

1.1 This guide is intended to provide a standardized approach for establishing and carrying out an air monitoring program to protect workers at waste management facilities. This guide may apply to routine operations at an active treatment, storage, or disposal site or the extraordinary conditions that can be encountered in opening and cleaning up a remedial action site.

1.2 Any user of this guide must understand that it is impossible to predict all the difficulties that could develop at a waste management facility due to hazardous airborne emissions. Although air contaminant measurements obtained in accordance with this guide may indicate acceptable or tolerable levels of toxic agents are present, care and judgment must still be exercised before concluding that all atmospheric contaminants at the site are under control.

Ключевые слова:
disposal; hazardous; airborne; emissions