(812) 309-78-59
(495) 223-46-76
ASTM D5130-95(2014)
Standard Test Method for Open-Channel Flow Measurement of Water Indirectly by Slope-Area Method (Withdrawn 2023)
12 стр.
Отменен
Электронный (pdf)Печатное издание
118.56 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
17.120.20 Flow. Including hydrometric determinations / Поток в открытых каналах
Сборник (ASTM):
11.01 Water (I) / Вода (I)
Тематика:
Water Testing
Описание
Причина отменыThis test method covers the computation of discharge (the volume rate of flow) of water in open channels or streams using representative cross-sectional characteristics, the water-surface slope, and coefficient of channel roughness as input to gradually-varied flow computations.

Formerly under the jurisdiction of Committee D19 on Water, this test method was withdrawn in January 2023 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

5.1 This test method is particularly useful for determining the discharge when it cannot be measured directly by some type of current meter to obtain velocities and with sounding weights to determine the cross section.

5.2 Even under optimum conditions, the personnel available cannot cover all points of interest during a major flood. Field personnel cannot always obtain reliable results by direct methods if the stage is rising or falling very rapidly, if flowing ice or debris interferes with depth or velocity measurements.

5.3 Under the worst conditions, access roads are blocked, cableways and bridges may be washed out, and knowledge of the flood frequently comes too late to obtain direct measurements of flow. Therefore, some type of indirect measurement is necessary. The slope-area method is a commonly used method.

Область применения

1.1 This test method covers the computation of discharge (the volume rate of flow) of water in open channels or streams using representative cross-sectional characteristics, the water-surface slope, and coefficient of channel roughness as input to gradually-varied flow computations.2,3

1.2 This test method produces an indirect measurement of the maximum discharge for one flow event, usually a specific flood. The computed discharge may be used to help define the high-water segment of a stage-discharge relation.

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
flood; open channel flow; water discharge