Standard Test Method for Mechanical Uniaxial Pre-strain and Thermal Free Recovery of Shape Memory Alloys
6 стр.
Действует
Печатное изданиеЭлектронный (pdf)
78.00 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
77.120.99 Other non-ferrous metals and their alloys / Цветные металлы и их сплавы прочие
Сборник (ASTM):
03.01 Metals -- Mechanical Testing; Elevated and Low-Temperature Tests; Metallography / Металлы - Механические испытания, Испытания при высоких и низких температурах, Металлография
Тематика:
Fatigue & Fracture
Описание
Значение и использование

5.1 This test method is used to measure a specimen's material and shape memory effect properties in response to a uniaxial deformation and then cycling through a full thermal transformation to recover all or a portion of the deformation. A material's martensite stiffness, martensite residual strain, austenite recovered strain, and unrecovered strain (or plastic deformation) after thermal cycling is determined.

5.2 Measurement of the specimen's motion closely parallels many shape memory applications and provides a result that is applicable to the function of the material.

5.3 This test method may be used for, but is not limited to, wire, round tube, or strip samples. It is able to provide an assessment of the product in its semi-finished form.

5.4 This test method provides a simple method for determining transformation temperatures by heating and cooling specimens through their full thermal transformation after uniaxial pre-straining in the martensite state.

5.5 This test method can be used on trained and processed material in a semi-finished form to measure Two Way Shape Memory Effect by comparing the strain in the austenite state and martensite states with no applied stress.

5.6 This test method is useful for quality control, specification acceptance, and research.

5.7 Transformation temperatures derived from this test method may not agree with those obtained by other test methods due to the effects of strain and stress on the transformation.

5.8 Components such as springs or other semi-finished parts can be tested using this method as agreed upon by the customer and supplier. Units of stress and strain can be replaced with force and displacement.

Область применения

1.1 This test method describes the heating and cooling a Shape Memory Alloy (SMA) specimen through transformation after uniaxial deformation to determine residual strain after loading and unloading, recovered strain on heating, total unrecovered strain upon cooling, and transformation temperatures.

1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Ключевые слова:
recovery strain; residual strain; shape memory alloy; thermoelastic alloy; transformation strain; transformation temperature;