(812) 309-78-59
(495) 223-46-76
ASTM C1449/C1449M-05
Standard Specification for Non-Asbestos Fiber-Cement Nonpressure Sewer Pipe
6 стр.
Заменен
Электронный (pdf)Печатное издание
78.62 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
23.040.50 Pipes and fittings of other materials / Трубы и фитинги из других материалов
Сборник (ASTM):
04.05 Chemical–Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete / Химически устойчивые неметаллические материалы; Глазированные керамические трубы; Трубы бетонные; изделия из фиброцемента; Известковые цементные растворы; Монолитный бетон; Сборный бетон
Тематика:
Masonry
Описание
Область применения

1.1 This specification covers requirements relating tonon-asbestos fiber-cement non-pressure sewer pipe, joints, andfittings suitable for use with gravity flow, intended for sewerageand drainage applications from point of use to point of treatmentor disposal. It defines certain conditions of manufacture,classification, characteristics, and acceptance tests applicable tothese products.

1.2 The values stated in either inch-pound units or SI units areto be regarded separately as standard. Within the text, the SIunits are shown in brackets. The values stated in each system arenot exact equivalents; therefore each system shall be usedindependently of the other. Combining values from the two systemsmay result in nonconformance with the specification.

Note 1—Rubber rings suitable for use with this pipe are coveredin Specification D 1869.

Note 2—This specification is issued for product standardizationand purchasing purposes only, and does not include requirements forinstallation or the relationships between operating conditions andthe strength characteristics of the various classifications ofpipe. The purchaser is cautioned that he must correlateinstallation and operating conditions with the specifiedcharacteristics of the pipe.

1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.

Ключевые слова:
drainage; fiber-cement; nonpressure; pipe; sewer;