(812) 309-78-59
(495) 223-46-76
ASTM D2671-00(2007)e1
Standard Test Methods for Heat-Shrinkable Tubing for Electrical Use
18 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
107.64 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
29.035.20 Plastics. Including adhesive tapes / Пластмассовые и резиновые изоляционные материалы. Включая клейкие ленты
Сборник (ASTM):
10.02 Electrical Insulation (II): D2519–latest / Электрическая изоляция (II): с D2518 и далее
Тематика:
Electrical Insulating Materials
Описание
Значение и использование

These test methods include most of the important tests used to characterize heat-shrinkable tubing. They are intended primarily for, but not limited to, extruded heat-shrinkable tubing.

Variations in these test methods or alternate contemporary methods of measurement may be used to determine the values for the properties in this standard provided such methods ensure quality levels and measurement accuracy equal to or better than those prescribed herein. It is the responsibility of the organizations using alternate test methods to be able to demonstrate this condition. In cases of dispute, the methods specified herein shall be used.

Note 2—Provision for alternate methods is necessary because of (1) the desire to simplify procedures for specific applications without altering the result, and (2) the desire to eliminate redundant testing and use data generated during manufacturing process control, including that generated under Statistical Process Control (SPC) conditions, using equipment and methods other than those specified herein. An example would be the use of laser micrometers or optical comparators to measure dimensions.

Область применения

1.1 These test methods cover the testing of heat-shrinkable tubing used for electrical insulation. Materials used include poly(vinyl chloride), polyolefins, fluorocarbon polymers, silicone rubber, and other plastic or elastomeric compounds.

1.2 The values stated in inch-pound units are the standard except for temperature, which shall be expressed in degrees Celsius. Values stated in parentheses are for information only.

1.3 The procedures appear in the following sections:

1.4 This is a fire-test-response standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections and .

Note 1

These test methods are similar, but not identical to, those in IEC 60684-2 (see also Note 0).

1.5 This is a fire-test-response standard. The test procedures measure the resistance of the tubing to ignition and propagation of flame after ignition under prescribed conditions of test.

1.6 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

Ключевые слова:
adhesive peel strength; brittleness temperature; color; color stability; copper corrosion; dielectric breakdown voltage; dielectric strength; flame resistance; fluid resistance; fungus resistance; heat resistance; heat shock; heat shrinkable tubing; inside diameter; length; low temperature; melting point; restricted shrinkage; secant modulus; specific gravity; storage life; stress modulus; temperature index; tensile strength; test methods; thermal endurance; thermal endurance graph; tubing; heat-shrinkable; ultimate elongation; volume resistivity; wall concentricity; wall thickness; water absorption