(812) 309-78-59
(495) 223-46-76
ASTM D4702-07
Standard Practice for Quality Management of Mechanical Coal Sampling Systems (Withdrawn 2008)
9 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
96.72 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
75.160.10 Solid. Including coal products, coke, peat, wood, derivatives of coal pyrolysis, etc. / Твердое топливо. Включая угольные продукты, кокс, торф, древесину и т.д.
Сборник (ASTM):
05.06 Gaseous Fuels; Coal and Coke; Catalysts; Bioenergy and Industrial Chemicals from Biomass / Газовое топливо; Уголь и кокс; Катализаторы; Биоэнергетика и промышленные химикаты из биомассы
Тематика:
Coal & Gas
Описание
Причина отмены

This practice is applicable to cross-belt, falling-stream, and auger sampling systems.

Formerly under the jurisdiction of Committee D05 on Coal and Coke, this practice was withdrawn in October 2008 and replaced by Practice D 7430 for Mechanical Sampling of Coal

Значение и использование

This practice addresses quality assurance criteria for operation of a mechanical coal-sampling system in accordance with Practice D 7256/D 7256M, Practice D 2013, and Practice D 4916. It provides recommendations for performance monitoring, inspection, and maintenance, which are necessary in maintaining a sampling system’capability to consistently obtain a representative sample.

Область применения

1.1 This practice is applicable to cross-belt, falling-stream, and auger sampling systems.

1.2 Spacing of increments pertains to the kind of interval between increments. Intervals can be defined in quantitative terms, such as units of time or mass, or in terms of position over the lot.

1.2.1 Spacing of Increments for Cross-Belt and Falling-Stream Samplers—Cross-belt and falling-stream type mechanical sampling systems take increments based on time, either at fixed time intervals or at random times during a fixed time strata. Some falling-stream samplers can take increments based on equal mass of coal sampled as determined by scales. The sections of this practice that pertain to cross-belt and falling-stream samplers describe procedures for only time-based sampling systems. This time-based inspection guideline will satisfy most criteria for mass-based or combination mass-based and time-based sampling systems. If there are items that are not covered, the inspector should refer to the manufacturer's literature.

1.2.2 Spacing of Increments for Auger Sampling—The spacing of increments collected by auger sampling systems is defined in terms of position over the lot.

1.3 It is essential that the inspector have the documentation listed in Section 2 of this practice when conducting an inspection.

1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 5.

Ключевые слова:
coal sampling; inspection; mechanical sampling; sampling systems