ASTM E214-05
Standard Practice for Immersed Ultrasonic Testing by the Reflection Method Using Pulsed Longitudinal Waves (Withdrawn 2007)
3 стр.
Заменен
Печатное изданиеЭлектронный (pdf)
84.24 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
Сборник (ASTM):
03.03 Nondestructive Testing (I): C1331 – E2373 / Неразрушающий контроль (I): C1331 – E2373
Тематика:
Nondestructive Testing
Описание
Причина отменыThis practice describes an ultrasonic examination procedure for detecting discontinuities in material using instruments that transmit and receive pulsed longitudinal ultrasonic waves introduced into the material to be examined while immersed in or impinged upon by a liquid coupling agent. This practice applies to any material that can conduct sound waves of an appropriate frequency, and can be immersed in a liquid coupling agent for inspection, or can be subject to inspection by the use of a column or stream of the couplant between the search unit and the material being examined.

Formerly under the jurisdiction of Committee E07 on Nondestructive Testing, this practice was withdrawn in May 2007 and replaced by Practice E 1001 for Detection and Evaluation of Discontinuities by the Immersed Pulse-Echo Ultrasonic Method Using Longitudinal Waves.

For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard's Document Summary page on the ASTM website.

Область применения

1.1 This practice² describes an ultrasonic examination procedure for detecting discontinuities in material using instruments that transmit and receive pulsed longitudinal ultrasonic waves introduced into the material to be examined while immersed in or impinged upon by a liquid coupling agent. This practice applies to any material that can conduct sound waves of an appropriate frequency, and can be immersed in a liquid coupling agent for inspection, or can be subject to inspection by the use of a column or stream of the couplant between the search unit and the material being examined.

Note 1—Practice E 1001 is a complementary document that extends Practice E 214 by describing more detailed procedures.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
immersed; Immersed Ultrasonic NDT; nondestructive examination; pulse-reflection method; pulsed longitudinal waves; ultrasonic nondestructive examination