ASTM F1555-94(2015)
Standard Guide for Characteristics for Extremity Splints (Withdrawn 2024)
2 стр.
Отменен
Электронный (pdf)Печатное издание
102.96 $ (включая НДС 20%)
Разработчик:
Зарубежные/ASTM
ICS:
11.160 First. Including kits, equipment, facilities and medical transport for first aid / Первая помощь. Включая аптечки, оборудование, учреждения и медицинский транспорт для оказания первой помощи
Сборник (ASTM):
13.02 Medical and Surgical Materials and Devices (II): F2502–Latest; Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment / Медицинские и хирургические материалы и приборы (II): F2502-Latest; Скорая медицинская помощь; Поиск и Спасение; Оборудование для анестезии и искусственного дыхания
Тематика:
Medical Services
Описание
Причина отменыThis guide covered minimum standards for devices, designated here as extremity splint(s) (ES), commonly known as splints.

Formerly under the jurisdiction of Committee F30 on Emergency Medical Services, this guide was withdrawn in January 2024 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

4.1 The intent of this guide is to identify characteristics that an ES should possess.

4.2 Varied clinical situations may require differing combinations of devices for adequate extremity immobilization, including traction or pneumatic devices, or both.

4.3 A device intended for use with adult patients shall accommodate the 95th percentile adult American male.

4.4 Devices that are labeled as intended for pediatric use shall not be required to accommodate adult patients.

Область применения

1.1 This guide covers minimum standards for devices, designated here as extremity splint(s) (ES), commonly known as splints. Extremity splints are designed to be used for the immobilization of an extremity by emergency medical service personnel.

1.2 This guide does not identify specific degrees of limitation of motion achieved by placement of a extrication device (ED) on a patient. Definitive requirements for immobilization of extremities in the out of hospital environment, and, in particular, the degree of limitation associated with the use of an ED in the out of hospital setting, have not been established in the medical literature.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Ключевые слова:
extremity splint; immobilization; splint ;