This specification covers plate, sheet, and strip of nickel-molybdenum alloys covering UNS N10001, N10665, N10675, N10629, and N10624 for use in general corrosive service. Product analysis shall be performed on the alloy and shall conform to the chemical composition requirement in nickel, molybdenum, iron, chromium, carbon, silicon, cobalt, manganese, phosphorus, sulfur, vanadium, nickel, molybdenum, aluminum, columbium, copper, tantalum, titanium, tungsten, zirconium, and magnesium. Sheet and strip shall undergo hot or cold rolling, solution annealing, and descaling unless solution annealed in atmosphere. Plates shall undergo hot or cold rolling, solution annealing, and descaling. The material shall conform to the required tensile properties such as tensile strength, yield strength, elongation, and Rockwell hardness. Sheet and strip shall conform to the specified grain size requirement
Область применения1.1 This specification2 covers plate, sheet, and strip of nickel-molybdenum alloys (UNS N10001, N10665, N10675, N10629, and N10624)* as shown in Table 1, for use in general corrosive service.
TABLE 1 Chemical RequirementsElement
Composition Limits, %
Alloy
N10001
Alloy
N10665
Alloy
N10675
Alloy
N10629
Alloy
N10624
Nickel
remainderA
remainderA
65.0 min
remainderA
Bal
Molybdenum
26.0–30.0
26.0–30.0
27.0–32.0
26.0–30.0
21.0-25.0
Iron
4.0–6.0
2.0 max
1.0–3.0
1.0–6.0
5.0-8.0
Chromium
1.0 max
1.0 max
1.0–3.0
0.5–1.5
6.0-10.0
Carbon, max
0.05
0.02
0.01
0.01
0.01
Silicon, max
1.0
0.10
0.10
0.05
0.10
Cobalt, max
2.5
1.00
3.0
2.5
1.0
Manganese,
max
1.0
1.0
3.0
1.5
1.0
Phosphorus,
max
0.04
0.04
0.030
0.04
0.025
Sulfur, max
0.03
0.03
0.010
0.01
0.01
Vanadium
0.2–0.4
...
0.20 max
...
...
Nickel plus
Molybdenum
...
...
94.0–98.0
...
Aluminum
...
...
0.50 max
0.1–0.5
0.5
Columbium
(Nb), max
...
...
0.20
...
Copper, max
...
...
0.20
0.5
0.5
Tantalum,
max
...
...
0.20
...
Titanium,
max
...
...
0.20
...
Tungsten,
max
...
...
3.0
...
Zirconium,
max
...
...
0.10
...
Magnesium,
max
...
...
...
...
...
A See Specification B906.TABLE 2 Mechanical Property RequirementsAlloy
Thickness,
in. (mm)
Tensile Strength,
min, psi (MPa)
Yield Strength
(0.2 % Offset),
min, psi (MPa)
Elongation
in 2 in.
(50.8 mm)
or 4DA
min, %
Rockwell
Hardness,B
max
Sheet and Strip
N10001
Under 3/16 (4.76)
115 000 (795)
50 000 (345)
45
100 HRB
N10665
Under 3/16 (4.76)
110 000 (760)
51 000 (350)
40
100 HRB
N10675
Under 3/16 (4.76)
110 000 (760)
51 000 (350)
40
100 HRB
N10629
Under 3/16 (4.76)
110 000 (760)
51 000 (350)
40
100 HRB
N10624
Under 3/16 (4.76)
104 000 (720)
46 000 (320)
40
100 HRB
Plate
N10001
3/16 to 21/2 in. (4.76 to 63.5 mm), incl
100 000 (690)
45 000 (310)
40
100 HRB
N10665
3/16 to 21/2 in. (4.76 to 63.5 mm), incl
110 000 (760)
51 000 (350)
40
100 HRB
N10675
3/16 to 21/2 in. (4.76 to 63.5 mm), incl
110 000 (760)
51 000 (350)
40
100 HRB
N10629
3/16 to 21/2 in. (4.76 to 63.5 mm), incl
110 000 (760)
51 000 (350)
40
100 HRB
N10624
3/16 to 21/2 in. (4.76 to 63.5 mm), incl
104 000 (720)
46 000 (320)
40
100 HRB
A D refers to the diameter of the tension specimen.B Hardness values are shown for information purposes only and are not to be used as a basis for rejection or acceptance. For approximate hardness conversions, see Hardness Conversion Tables E140.1.2 The following products are covered under this specification:
1.2.1 Sheet and Strip—Hot or cold rolled, solution annealed, and descaled unless solution anneal is performed in an atmosphere yielding a bright finish.
1.2.2 Plate—Hot or cold rolled, solution annealed, and descaled.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Material Safety Data Sheet (MSDS) for this product/material as provided by the manufacturer, to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.