18.1 For purposes of determining compliance with the specified limits for requirements of the properties listed in the following table, and observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29.
Property
Rounded Unit for Observed or Calculated Value
Chemical composition
nearest unit in the last right-hand place of figures of the specified limit
Tensile strength
Yield strength
nearest ksi (nearest MPa up to 10 ksi, incl, nearest 5 MPa over 10 ksi)
Elongation
nearest 1 %
This specification covers welded copper-nickel alloy pipes produced from Copper Alloy UNS Nos. C70600 and C71500 for general engineering applications. Pipes may be produced in any one of the following tempers: as-welded from annealed sheets, strips, or plates (WM50); as-welded from cold-worked sheets, strips, or plates (WM00, WM01, WM02, and so forth); welded and annealed (WO50); welded, light cold drawn (WR00) or hard cold drawn (WR04), and stress relieved; or fully finished as annealed, light drawn (WH00) or hard drawn (WH04), and stress relieved. Products shall be sampled and prepared, then tested accordingly to examine their conformance to dimensional (outside diameter, specific and stock lengths, wall thickness, squareness of cut, and roundness), mechanical (tensile and yield strengths, and elongation), and chemical composition requirements. Specimens shall also undergo nondestructive tests such as radiographic examination, eddy-current test, and hydrostatic test.
Область применения1.1 This specification establishes the requirements for welded copper-nickel alloy pipe for general engineering purposes. The following alloys are covered:2
Copper Alloy
UNS No.2
Type of Metal
C70600
90-10 copper-nickel
C70620
90-10 copper-nickel
(Modified for Welding)
C71500
70-30 copper-nickel
C71520
70-30 copper-nickel
(Modified for Welding)
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.