14.1 Calculated values shall be rounded to the specified number of places in accordance with Practice E29.
РефератThis specification establishes the requirements for high conductivity, tough-pitch, copper wire bars, cakes, slabs, billets, ingots, and ingot bars. Copper wires under this specification include UNS C113000, C11400, C11500 and C11600, C12000, C12200, C12300, and C14500. The maximum values of mass resistivity for wire bars, cakes, slabs, and billets, for electrical use and for other uses, shall conform to the specified requirements. Samples for the electrical resistivity test of electrolytic copper, electrorefined copper, electrowon copper, and fire-refined copper shall be fabricated into a rod. The external oxide shall be removed, the rod cold drawn into a wire of a specific diameter, and cut into sampling lengths. The resulting specimen shall be annealed and quickly cooled in an inert atmosphere. The mean resistivity shall be determined as the mean of the observations from the test on the wires.
Область применения1.1 This specification establishes the requirements for high conductivity, tough-pitch, copper wire bars, cakes, slabs, billets, ingots, and ingot bars.
1.2 Copper under this specification corresponds to the designations “ETP” (UNS C11000) and “FRHC” (UNS C11020) as shown in Classification B224. These coppers may also be used to produce coppers corresponding to the following:
Copper UNS No.
Classification B224 Designation
C11300, C11400, C11500, and C11600
STP
C12000
DLP
C12200
DHP
C12300
DHPS
C14520
DPTE
1.3 Although this specification includes certain UNS designations as described in Practice E527, these designations are for cross reference only and are not specification requirements. Therefore, in case of conflict, this ASTM specification shall govern.
1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4.1 Exception—Electrical resistivity is expressed in SI units.