This specification2 covers rod of low-carbon nickel-chromium- molybdenum alloys (UNS N10276, N06022, N06035, N06455, N06058, and N06059), low-carbon nickel-molybdenum- chromium-tantalum (UNS N06210), low-carbon nickel-chromium-molybdenum-copper alloy (UNS N06200), and low-carbon nickel-chromium-molybdenum-tungsten (UNS N06686), for use in general corrosive service. Product and chemical analyses shall be performed on the materials and shall conform to the required chemical composition in molybdenum, chromium, iron, tungsten, cobalt, carbon, silicon, manganese, vanadium, phosphorus, sulfur, titanium, nickel, aluminum, copper, and tantalum. Tension test shall be performed and shall comply to required mechanical properties for hot or cold finished, solution annealed rods such as tensile strength, yield strength, and elongation.
Область применения1.1 This specification2 covers rod of low-carbon nickel-chromium-molybdenum alloys (UNS N10276, N06022, N06035, N06044, N06455, N06058, and N06059), low-carbon nickel-molybdenum-chromium (USN N10362), low-carbon nickel-molybdenum-chromium-tantalum (UNS N06210), low-carbon nickel-chromium-molybdenum-copper alloy (UNS N06200), and low-carbon nickel-chromium-molybdenum-tungsten (UNS N06686) as shown in Table 1, for use in general corrosive service.
TABLE 1 Chemical Requirements
Element
Composition Limits, %
Alloy
N06035
Alloy
N06044
Alloy
N10276
Alloy
N06022
Alloy
N06455
Alloy
N06059
Alloy
N06058
Alloy
N06200
Alloy
N10362
Alloy
N06210
Alloy
N06686
Molybdenum
7.60–9.00
0.80-1.20
15.0–17.0
12.5–14.5
14.0–17.0
15.0–16.5
18.5–21.0
15.0–17.0
21.5-23.0
18.0–20.0
15.0-17.0
Chromium
32.25–34.25
43.5-45.3
14.5–16.5
20.0–22.5
14.0–18.0
22.0–24.0
20.0- 23.0
22.0–24.0
13.8-15.6
18.0–20.0
19.0-23.0
Iron
2.00 max
0.3 max
4.0–7.0
2.0–6.0
3.0 max
1.5, max
1.5, max
3.0 max
1.25 max
1.0 max
5.0 max
Tungsten
0.60 max
...
3.0–4.5
2.5–3.5
...
...
0.3 max
...
...
...
3.0-4.4
Cobalt, max
1.00
...
2.5
2.5
2.0
0.3
0.3 max
2.0 max
...
1.0
...
Carbon, max
0.050
0.02
0.010
0.015
0.015
0.010
0.010
0.010
0.010
0.015
0.010
Silicon, max
0.60
0.20
0.08
0.08
0.08
0.10
0.10
0.08
0.08
0.08
0.08
Manganese, max
0.50
0.07-0.30
1.0
0.50
1.0
0.5
0.5
0.5
0.60
0.5
0.75
Vanadium, max
0.20
...
0.35
0.35
...
...
...
...
...
0.35
...
Phosphorus, max
0.030
0.020
0.04
0.02
0.04
0.015
0.015
0.025
0.025
0.02
0.04
Sulfur, max
0.015
0.020
0.03
0.02
0.03
0.010
0.010
0.010
0.010
0.02
0.02
Titanium
...
0.10-0.30
...
...
0.7 max
...
...
...
...
...
0.02-0.25
Nickel
remainderA
Bal
remainderA
remainderA
remainderA
Bal
Bal
remainderA
remainderA
remainderA
remainderA
Aluminum
0.40 max
0.30 max
...
...
...
0.1–0.4
0.40 max
0.50 max
0.50 max
...
...
Copper
0.30 max
...
...
...
...
0.50 max
0.50 max
1.3–1.9
...
...
...
Tantalum
...
...
...
...
...
...
...
...
...
1.5–2.2
...
Nitrogen
...
...
...
...
...
...
0.02–0.15
...
...
...
...
(A) See 12.1.1.TABLE 2 Permissible Variations in Diameter and Out-of-Roundness of As Cold Finished Rods
Specified Diameter, in. (mm)
Permissible Variations, in. (mm)
Diameter
Out of Roundness, max
+
−
1/4 –7/16 (6.35–11.11), incl
0.012 (0.30)
0.012 (0.30)
0.018 (0.46)
Over 7/16 –5/8 (11.11–15.87), incl
0.014 (0.36)
0.014 (0.36)
0.020 (0.51)
Over 5/8 –3/4 (15.87–19.05), excl
0.016 (0.41)
0.016 (0.41)
0.024 (0.61)
3/4 –31/2 (19.05–88.9), incl
0.010 (0.25)
0.010 (0.25)
0.010 (0.25)
TABLE 3 Mechanical Property Requirements for As Cold Finished Rods
Alloy
Grade
Tensile Strength, min, psi (MPa)
Yield Strength (0.2 % Offset), min, psi
(MPa)
Elongation in 2 in.
(50.8 mm) or 4DA
min, %
N06059
1
120 (827)
85 (586)
20
2
135 (931)
125 (862)
20
3
160 (1103)
150 (1034)
15
N06686
1
120 (827)
85 (586)
20
2
135 (931)
125 (862)
20
3
160 (1103)
150 (1034)
20
(A) D refers to the diameter of the tension specimen.TABLE 4 Permissible Variations in Diameter and Out-of-Roundness of Hot or Cold Finished, Solution Annealed Rods
Specified Diameter, in. (mm)
Permissible Variations, in. (mm)
Diameter
Out of Roundness, max
+
−
5/16 Hot-Finished, Annealed, and Descaled Rods
5/16 –7/16 (7.94–11.11), incl
0.012 (0.30)
0.012 (0.30)
0.018 (0.46)
Over 7/16 –5/8 (11.11–15.87), incl
0.014 (0.36)
0.014 (0.36)
0.020 (0.51)
Over 5/8 –3/4 (15.87–19.05), excl
0.016 (0.41)
0.016 (0.41)
0.024 (0.61)
Hot-Finished, Annealed, and Ground or Turned Rods
3/4 –31/2 (19.05–88.9), incl
0.010 (0.25)
0
0.008 (0.20)
TABLE 5 Mechanical Property Requirements for Hot or Cold Finished, Solution Annealed Rods
Alloy
Tensile Strength, min, psi (MPa)
Yield Strength (0.2 % Offset), min, psi
(MPa)
Elongation in 2 in.
(50.8 mm) or 4DA
min, %
N10276
100 000 (690)
41 000 (283)
40
N06022
100 000 (690)
45 000 (310)
45
N06035
85 000 (586)
35 000 (241)
30
N06044
100 000 (690)
45 000 (310)
30
N06455
100 000 (690)
40 000 (276)
40
N06058
110 000 (760)
52 000 (360)
40
N06059
100 000 (690)
45 000 (310)
45
N06200
100 000 (690)
45 000 (310)
45
N10362
105 000 (725)
45 000 (310)
40
N06686
100 000 (690)
45 000 (310)
45
N06210
100 000 (690)
45 000 (310)
45
(A) D refers to the diameter of the tension specimen.1.2 The following products are covered under this specification:
1.2.1 Rods 5/16 to 3/4 in. (7.94 to 19.05 mm), exclusive, in diameter, hot or cold finished, solution annealed and pickled, or mechanically descaled.
1.2.2 Rods 3/4 to 31/2 in. (19.05 to 88.9 mm), inclusive, in diameter, hot or cold finished, solution annealed, ground or turned.
1.2.3 Rods 1/4 to 3 1/2 in. (6.35 to 88.9 mm), inclusive, in diameter, solution annealed, cold finished, as cold finished, ground or turned (N06059 and N06686 only, see Table 2 and Table 3).
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Safety Data Sheet (SDS) for this product/material as provided by the manufacturer, to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.