The tests in this test method are designed to assess the resistance stability of electrical contacts or connections.
The described procedures are for the detection of events that result from short duration, high-resistance fluctuations, or of voltage variations that may result in improper triggering of high speed digital circuits.
In those procedures, the test currents are 100 mA (±20 mA) when the test sample has a resistance between 0 and 10 Ω. Since the minimum resistance change required to produce an event (defined in 3.2.1) is specified as 10 Ω (see 1.3), the voltage increase required to produce this event must be at least 1.0 V.
The detection of nanosecond-duration events is considered necessary when an application is susceptible to noise. However, these procedures are not capable of determining the actual duration of the event detected.
The integrity of nanosecond-duration signals can only be maintained with transmission lines; therefore, contacts in series are connected to a detector channel through coaxial cable. The detector will indicate when the resistance monitored exceeds the minimum event resistance for more than the specified duration.
The test condition designation corresponding to a specific minimum event duration of 1, 10, or 50 ns is listed in Table 1. These shall be specified in the referencing document.
TABLE 1 Test Condition Designations for Specific Minimum Event Durations
Test ConditionEvent Duration, min A 1 nanosecond B10 nanoseconds C50 nanoseconds Область применения1.1 This test method describes equipment and techniques for detecting contact resistance transients yielding resistances greater than a specified value and lasting for at least a specified minimum duration.
1.2 The minimum durations specified in this standard are 1, 10, and 50 nanoseconds (ns).
1.3 The minimum sample resistance required for an event detection in this standard is 10 Ω.
1.4 An ASTM guide for measuring electrical contact transients of various durations is available as Guide B 854.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.