Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM B956-10

Заменен
Standard Specification for Welded Copper and Copper-Alloy Condenser and Heat Exchanger Tubes with Integral Fins — 9 стр.
Реферат

This specification establishes the requirements for forge-welded copper and copper alloy with integral fins for use in surface condenser, evaporator, and heat exchanger. The product shall be welded tube of one of the following Copper or Copper Alloy UNS Nos.: C12000, C12200, C19200, C23000, C44300, C44400, C44500, C68700, C70400, C70600, C70620, C71000, C71500, C71520, and C72200. The material heat identification or traceability shall be specified if required. The product shall be manufactured by cold forming to produce an integral enhanced surface for improved heat transfer and shall typically be furnished with unenhanced ends, but may be furnished with enhanced ends or stripped ends. Temper conditions (annealed, WO61 or light cold-worked, WC55) for the tubes and the enhanced and unenhanced sections of the tubes are given. The material shall conform to the chemical composition requirements prescribed for copper, tin, aluminum, nickel, cobalt, lead, iron, zinc, manganese, arsenic, antimony, phosphorus, chromium, and other elements such as carbon, sulfur, silicon, and titanium as determined by chemical analysis. Requirements for grain size, dimensions, mass, and mechanical properties including tensile strength and yield strength as determined by tension test are detailed. The performance requirements including expansion, flattening, and reverse bend tests; mercurous nitrate test or ammonia vapor test; and nondestructive tests such as eddy-current, hydrostatic, and pneumatic tests are detailed as well.

Область применения

1.1 This specification establishes the requirements for heat exchanger tubes manufactured from forge-welded copper and copper alloy tubing in straight lengths on which the external or internal surface, or both, has been modified by cold forming process to produce an integral enhanced surface for improved heat transfer.

1.2 UnitsThe values stated in either inch-pounds units or SI units are to be regarded separately as the standard. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems could result in non-conformance with the specification.

1.2.1 Within the text, the SI units are shown in brackets.

1.3 The tubes are typically used in surface condensers, evaporators, and heat exchangers.

ICS
27.060.30 Boilers. Including steam pressure vessels / Котлы и теплообменники
Сборник ASTM
02.01 Copper and Copper Alloys / Медь и сплавы из меди
Тематика
Copper