The test for resistance to freezing and thawing functions as a guide to the selection of ceramic tile suitable for outdoor service in geographic areas subjected to freezing. It can serve as a test method to verify compliance with specifications for ceramic tile, and provides a control test for determining the uniformity of tile being manufactured for exterior installations.
FIG. 1 Schematic Diagram of Apparatus
1.1 This test method describes the procedures and equipment required to test either glazed or unglazed ceramic tile for resistance to repeated cycles of freezing and thawing. Ceramic tile of any size or shape may be tested by this test method.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.