Formerly under the jurisdiction of Committee C17 on Fiber-Reinforced Cement Products, this specification was withdrawn in November 2019. This standard is being withdrawn without replacement due to its limited use by industry.
РефератThis specification covers various classes of asbestos-cement products (other than fill for cooling towers) such as drift eliminators or demisters, louvers, partitioning and casing panels, pressure pipes, and nonpressure or gravity drainage pipes. Products cured at atmospheric pressure or by autoclaving are also covered. Products shall adhere to the following tests and property requirements: apparent density, water absorption, flexural strength, modulus of rupture, freeze-thaw resistance, Harkort test, and dimensions.
Область применения1.1 This specification covers drift eliminators or demisters, louvers, partitioning and casing panels.
Note 1: Asbestos-cement pipes are covered in Specifications C296 and C428; and asbestos-cement heat exchange fill products are covered in Specification C1082 for flat fill and Specification C1081 for corrugated fill.
1.2 The following classes of products are covered:
Paragraph
Classifications
Drift eliminators or demisters
4.1
Classes 1, 2 and 3
Louvers
4.2
Classes 1 and 2
Casing panels
4.3
Classes 1 and 2
Asbestos-cement pressure pipes
4.4
Classes 100, 150, and 200
Asbestos-cement nonpressure or gravity drainage pipes
4.5
Classes 1500, 2400, 3300, 4000, and 5000
1.2.1 Products cured at atmospheric pressure or by autoclaving are covered.
1.3 The values stated in the SI system are to be regarded as the standard. The inch-pound units in parentheses are provided for information only.
1.4 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to “Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.”2
1.5 The following safety hazards caveat pertains only to the test method portion of this specification (Section 5): This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. For a specific safety hazard, see .