5.1 Chemical-resistant polymer machinery grouts are used to provide precision support for machinery or equipment.
Note 2: The machinery or equipment or support bases or plates, or combination thereof, are positioned to the precise elevation and location required. The bases or plates are typically placed on prepared foundations and supported on temporary shims or support bolts (jack screws). Forms are installed to contain the flowable grout. The grout is poured around the perimeter in such a manner as to allow the grout to flow around and under the equipment base or plates. The grout subsequently hardens to provide a strong rigid support layer capable of withstanding the stresses transferred by the equipment to the foundation. Although the actual machinery base plate is typically metal and the cover plate in this test uses acrylic glass, different grouts using acrylic glass cover plates has proven useful for comparative purposes as described in this test in laboratory conditions.
5.2 In addition to the required physical properties of the grout, the flow and bearing area achieved are important considerations for effective grout installation. The two characteristics measured by this test method are flow and bearing area.
5.3 The flow test simulates typical application conditions for a flowable polymer machinery grout in a laboratory environment. It may be used to evaluate the suitability of a particular grout for a specific application, to compare the flowability and bearing area of two or more grouts, or to evaluate the effects of formulation changes, temperature, mixing techniques, or other factors on flowability.
5.4 The estimated amount of upper grout surface contact in percent can be used to compare two or more grouts or show the effects of temperature, formulation changes, or other factors on bearing area. A limited set of results using visual guides (see Fig. 1 and Fig. 2) is used to classify the bearing as “high”—greater than 85 %,” “medium—70 to 85 %,” and “low—less than 70 %.”
Область применения1.1 This test method covers the measure of flowability of chemical-resistant polymer machinery grouts as evaluated in a 50-mm [2-in.] or 25-mm [1-in.] pour thickness in a laboratory setting. The test method provides for the assessment of upper surface plate contact area (bearing area). These grouts will typically be at least two component formulations that may be used for installations where grout thickness will range from 25 mm to 150 mm [1 in. to 6 in.] underneath the base or plates being grouted.
1.2 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.