Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM C520-04(2010)

Заменен
Standard Test Methods for Density of Granular Loose Fill Insulations — 3 стр.
Значение и использование

Method A will be used primarily as a manufacturing quality control and field test method without the need for conditioning. For more accurate research purposes, conditioning shall be specified.

Method B will be used, when specified, to determine the density at which insulation properties such as thermal resistance and placement coverage are to be determined.

Область применения

1.1 These test methods are applicable to granular loose fill insulation materials such as vermiculite and perlite. They are used for other insulation materials with similar flow and settling properties.

1.2 Method A shall be used to determine bulk density.

1.3 Method B shall be used to determine design density and, with Method A, is used to calculate percent loss of volume due to settling.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
91.100.60 Thermal and sound insulating materials / Тепло- и звукоизоляционные материалы
Сборник ASTM
04.06 Thermal Insulation; Building and Environmental Acoustics / Теплоизоляция; Внутренняя звукоизоляция зданий и звукоизоляция от внешней среды
Тематика
Thermal Insulation