This specification covers installation procedures for lock-strip gaskets and for infill glazing materials in lock-strip gasket glazing applications used in building walls. The prime performance considerations are weathertightness against air and water infiltration, and structural integrity under wind loads. H-type gasket and reglet-type gasket are types of single-opening gasket systems which should be installed according to the specified requirements. Installation of multiple-opening gasket systems shall be classified as: unsupported vertical ladder assembly; unsupported horizontal ladder assembly; supported vertical ladder assembly; supported horizontal ladder assembly; and grid assembly. Installation of stick system, glass or panel into gasket, and lock-strip shall be in accordance with the requirements specified.
Область применения1.1 This specification covers installation procedures for lock-strip gaskets that comply with Specification C 542 and for infill glazing materials in lockstrip gasket glazing applications used in building walls which are not more than 15 from a vertical plane. The prime performance considerations are weathertightness against air and water infiltration, and structural integrity under wind loads.
1.2 The values stated in inch-pound units are to be regarded as the standard. The SI units in parentheses are provided for information only.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.