1.1 This test method covers the determination of lead and cadmium extracted by acetic acid from the lip and rim area of glassware used for drinking and which is exteriorly decorated with ceramic glass enamels. The procedure of extraction may be expected to accelerate the release of lead and cadmium from the decorated area and to serve, therefore, as a severe test that is unlikely to be matched under the actual conditions of usage of such glassware. This test method is specific for lead and cadmium.
Note 1-For additional information see Test Method C738.1.2 The values stated in acceptable metric units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.