Control—The following tests are useful for control purposes during the manufacture and use of varnishes, and for determining the uniformity of batches:
Specific gravity,
Viscosity,
Flash point, and
Nonvolatile matter by weight.
Performance—The following tests are useful for determining the performance of varnishes during application and use:
Drainage,
Time of drying,
Build,
Dielectric strength,
Thermal endurance,
Varnish compatibility,
Salt water proofness, and
Oil resistance.
Область применения1.1 These test methods cover tests for solvent containing varnishes primarily intended to provide electrical, mechanical, and chemical protection for electrical equipment. These test methods include tests for control and performance as follows:
ProcedureSection Build37-41 Dielectric Strength42-47 Drainage25-31 Flash Point17-19 Nonvolatile Matter20-24 Oil Resistance53-55 Preparation of Test Specimens 7 Specific Gravity 9-12 Temperature Index48-49 Time of Drying32-36 Varnish Compatibility50-52 Viscosity13-161.2 Where the entire test method is included in this standard, the precision and bias are not known unless given in the stated method.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.
Note 1—There is no equivalent IEC standard.