ASTM D202-08

Заменен
Standard Test Methods for Sampling and Testing Untreated Paper Used for Electrical Insulation — 35 стр.
Значение и использование

In the buyer-seller relationship it is necessary that an understanding exists as to the expected nominal characteristics of the product, and the magnitude of permissible departure from the nominal values. Also, it is necessary that an agreement be reached as to how many units of a lot can fall outside of the specification limits without rejection of the lot. It is this latter subject that is addressed by this test method.

Область применения

1.1 These test methods cover procedures for sampling and testing untreated paper to be used as an electrical insulator or as a constituent of a composite material used for electrical insulating purposes.

1.1.1 Untreated papers are thin, fibrous sheets normally laid down from a water suspension of pulped fibers (usually cellulosic), which may contain various amounts of nonfibrous ingredients, and which are calendared, if required, to obtain desired thickness and density. Nevertheless, these test methods are applicable, generally although not invariably, to papers formed by other means, to papers modified (during or after formation) by additions, and to papers given subsequent mechanical treatments such as creping.

1.1.2 As an electrical insulating and dielectric material, paper is considered untreated until it is subjected to a manufacturing process such as drying, impregnation, or varnish treatment.

1.1.3 The test methods given herein were developed specifically for papers having a thickness of 0.75 mm (0.030 in.) or less. A number of these test methods are also suitable for use on other materials such as pulps or boards. Refer to Test Methods D 3376 or Methods D 3394 to determine which tests are applicable to pulps or electrical insulating boards. In the paper industry, some products in thicknesses of less than 0.75 mm are termed paperboard. Such products are included within the scope of these methods.

1.1.4 These test methods are applicable to flexible fibrous-mat materials formed from suspensions of fiber in fluids other than water. These mats may have thicknesses approaching 2 mm, and may contain fibers that are natural, synthetic, organic, or inorganic; fillers that are natural, synthetic, organic, or inorganic; and flexible polymeric binder materials.

1.2 The procedures appear in the following sections:

ProcedureSectionsASTM or TAPPI
Reference
(Modified) Absorption (Rise of Water) 78 to 83... Acidity-Alkalinity-pH 45 to 54E 70 Air Resistance 98 to 101D 726 Aqueous Extract Conductivity 55 to 64... Ash Content 40 to 44D 586 Bursting Strength102 to 107D 774 Chlorides (Water-Extractable)165 to 183... Conditioning 15D 6054 Conducting Paths138 to 151... Density, Apparent 29 to 33... Dielectric Strength152 to 157D 149 Dimensions of Sheet, Rolls and
Cores 16 to 24D 374 Dissipation Factor and Permittivity158 to 164D 150 Edge-Tearing Resistance126 to 130D 827 Fiber Analysis 74 to 77D 1030 Folding Endurance108 to 110T 423 and D2176 Grammage 25 to 28D 646 Permittivity158 to 164D 150 Heat Stability in Air131 to 137D 827 Impregnation Time 84 to 91... Internal-Tearing Resistance121 to 125D 689 or T414 Moisture Content 34 to 39D 644 and D3277 Particulate Copper193 to 202... Particulate Iron184 to 192... Reagents 4D 1193 Reports 14E 29 Sampling 6 to 13D 3636 Silver Tarnishing by Paper and
Paperboard203 to 206T 444 Solvent-Soluble Matter 65 to 73... Surface Friction 92 to 97D 528 and T455 Tensile Properties111 to 120D 76, E4 Thickness (see Dimensions) 16 to 24D 374

1.3 The tests for Holes and Felt Hair Inclusions and the Stain Test for Fine Pores, have been removed from this compilation of test methods. These test methods were specific to grades of capacitor paper formerly covered by Specification D 1930, which has been withdrawn.

Note 1—This compilation of test methods is closely related to IEC Publication 60554-2. Not all of the individual methods included herein are included in IEC 60554-2, nor are all of the methods in IEC 60554-2 included in this standard. The individual procedures as described in the two standards are in general sufficiently close to each other that it is reasonable to expect that test results obtained by most of the procedures specified in either standard will not differ significantly. However, before assuming that a procedure in these test methods is exactly equivalent to an IEC 60554-2 procedure, the written procedures should be compared closely, and if it seems advisable, test results by the two procedures should be compared.

1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See 43.2.1, 71.1, 143.1, 148.1 and 156.1 for specific hazards.

ICS
29.035.10 Paper and board insulating materials / Бумажные и картонные изоляционные материалы
Сборник ASTM
10.01 Electrical Insulation (I): D69–D2484 / Электрическая изоляция (I): D69-D2484
Тематика
Electrical Insulating Materials