Normally, results obtained by this test method are reproducible under comparable laboratory conditions. However, it must not be expected that results obtained by different operators at various laboratories and times will be in exact agreement due to some seemingly minor procedural change. Moreover, results for longer fiber grades are influenced to a greater extent by differences in fiber length distribution and characteristics than those of shorter grades.
Область применения1.1 This test method covers the determination of the length distribution and fines content of milled asbestos fiber by wet classification employing the McNett fiber classifier.
1.2 The values stated in SI units are the standard. The inch-pound units shown in parentheses are provided for information only.
1.3 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to “Safe Use of Chrysotile: A Manual on Preventive and Control Measures.”
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.