ASTM D3032-16

Заменен
Standard Test Methods for Hookup Wire Insulation — 41 стр.
Реферат

These test methods detail the standard procedures for testing hookup wire insulations including all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness or flat ribbon cable. The insulating materials include not only the primary insulation over the conductor, but also insulating jackets over shielded constructions. The test procedures covered here shall be performed in the conditions or shall determine the properties, as follows: axial stability (longitudinal change) after thermal exposure; bondability to potting compounds; capacitance; cold bend test; concentricity; crush resistance; dielectric breakdown voltage; dimensions; dry-arc tracking; dynamic cut-through; fluid immersion; high temperature shock; insulation-continuity proof tests; insulation resistance; partial discharge (corona) inception and extinction voltage; relative thermal life and temperature index; strip force; surface resistance; tensile properties; vertical flame test; voltage rating of hook-up wire; voltage withstand test; and wet arc-tracking.

Область применения

1.1 These test methods cover procedures for testing hookup wire.

1.2 For the purposes of these test methods, hookup wire insulation includes all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness or flat ribbon cable. The insulating materials include not only the primary insulation over the conductor, but also insulating jackets over shielded constructions.

1.3 The test procedures and their locations are as follows:

 

Section

Axial Stability (Longitudinal Change) After Thermal Exposure

21

Bondability of Insulation to Potting Compounds

19

Capacitance

9 to 12

Cold Bend Test

26

Concentricity

16

Crush Resistance

20

Dielectric Breakdown Voltage

5

Dimensions

15

Dry-Arc Tracking

29

Dynamic Cut-Through

22

Fluid Immersion

23

High Temperature Shock

24

Insulation-Continuity Proof Tests

13

Insulation Resistance

6

Partial Discharge (Corona) Inception and Extinction Voltage

25

Relative Thermal Life and Temperature Index

14

Strip Force

27

Surface Resistance

7

Tensile Properties

17

Vertical Flame Test

18

Voltage Rating of Hook-Up Wire

A2

Voltage Withstand Test

8

Wet Arc-Tracking

28

1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see 12.2.1, 12.4.1.8, 18.1.3, Note 17, and 25.4.

ICS
29.060.10 Wires. Including electric rods, busbars, etc. / Провода. Включая стержни, шины и т.д.
Сборник ASTM
10.02 Electrical Insulation (II): D2519–latest / Электрическая изоляция (II): с D2518 и далее
Тематика
Electrical Insulating Materials