This test method is used to determine the effect of exposure to elevated temperatures on the bond strength of combinations of magnet wire insulations and electrical insulating varnishes. The results are used as a guide for the comparison and selection of varnishes and combinations of varnishes and magnet wire insulation for specific applications. Test Methods D 1932, D 3251, and D 3850 describe additional tests for determining the thermal endurance of insulating varnishes. A comprehensive evaluation of thermal characteristics should include a comparison of the thermal endurance determined in these different ways.
This test method is useful for research and product qualifications purposes.
Область применения1.1 This test method covers the determination of the thermal endurance of electrical insulating varnishes alone or in combinations with wire insulation. Changes in the helical coil bond strength are used as the test criteria. The coils can be made from bare aluminum or copper wire, or from film- or fiber-insulated magnet wire.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Section 7.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
Note—There is no similar or equivalent IEC standard.