1.1 This test method covers the determination of diesel fuel as a contaminant in used lubricating oil. The method is limited to SAE 30 oil.
Note 1-This test method may be applicable to higher viscosity grade oils. However, such oils were not included in the program used to develop the precision statement.1.2 There is some overlap of the boiling ranges of diesel fuel and SAE 30 engine oils. Moreover, the boiling range of SAE 30 oils from various sources can vary appreciably. As a result, the calibration can be altered by as much as 2%, in terms of fuel dilution. When testing unknown or mixed brands of used engine oil, it should be realized that the precision of the method may be poorer than the precision obtained when calibrating with a new oil representative of the used oil being tested.
1.3 The values stated in SI units are to be regarded as the standard. The values stated in inch-pound units are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.