This test method covers the determination of low temperature flow behavior, through a screen-type test filter, of aviation turbine fuels, which can contain separated solids as wax.
This test method is being balloted for withdrawal with no replacement because it has been removed as a Referenced Document from Specification D1655 by Subcommittee D02.J0 due to its inability to detect contamination in jet fuel.
Formerly under the jurisdiction of Committee D02 on Petroleum Products and Lubricants, this test method was withdrawn in May 2010.
Значение и использованиеThe lowest temperature at which aviation fuels remain free of solid hydrocarbon crystals, which may restrict the flow of fuel through filters in an aircraft fuel system, is a key safety parameter in the specification and use of fuels. In Test Method D 2386, the freezing point is defined as the temperature at which all crystals disappear following a cooling and warming cycle. In this test method, a cooling and warming cycle is also employed; however, the test result is defined as the flow point, which is the temperature of the specimen at which a test filter becomes unblocked on warming.
Область применения1.1 This test method covers the determination of low temperature flow behavior, through a screen-type test filter, of aviation turbine fuels, which can contain separated solids as wax.
1.2 Procedure A employs a 26-μm test filter and is the recommended procedure. Some existing instruments are fitted with a 42-μm filter, and Procedure B is retained to enable their continued use.
1.3 The use of Procedure A (26-μm test filter) with fuels that have a viscosity of greater than 5.0 mm2/s (cSt) at -20°C, as determined by Test Method D 445, can affect the precision and the simulated freezing point obtained on such fuels and can give a higher (warmer) result than the conventional freezing point obtained by Test Method D 2386.
Note 1—The principle of this test method relies on flow through a fine-mesh test filter, and, hence, the result can be affected by the viscosity of the sample. When using Procedure A, a no-flow condition is reached when crystals block the test filter or the viscosity exceeds about 14 mm2/s (cSt); sample with a viscosity of greater than 5 mm2/s (cSt) at -20°C may exceed the 14-mm2/s (cSt) threshold at a temperature before crystals are formed. If viscosity affects the result before crystals are formed, then the reported value of the no-flow temperature of the sample will always be warmer than the actual freezing point, and therefore fail-safe and an indicator of possible flow anomalies at low temperature.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.