5.1 Sampling from the vadose zone may be an important component of some groundwater monitoring strategies. It can provide information regarding contaminant transport and attenuation in the vadose zone. This information can be used for mitigating potential problems prior to degradation of a groundwater resource (1).3
5.2 The choice of appropriate sampling devices for a particular location is dependent on various criteria. Specific guidelines for designing vadose zone monitoring programs have been discussed by Morrison (1), Wilson (2), Wilson (3), Everett (4), Wilson (5), Everett, et al (6), Wilson (7), Everett, et al (8), Everett, et al (9), Robbins, et al (10), Merry and Palmer (11), U.S. EPA (12), Ball (13), and Wilson (14). In general, it is prudent to combine various unsaturated and free drainage samplers into a program, so that the different flow regimes may be monitored.
5.3 This guide does not attempt to present details of installation and use of the equipment discussed. However, an effort has been made to present those references in which the specific techniques may be found.
Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it and the suitability of the equipment and facility used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/observation/ and the like. Users of this standard are cautioned that compliance with Practice D3740 does not itself guarantee reliable results. Reliable results depend on many factors; D3740 provides a means of evaluating some of those factors.
Область применения1.1 This guide covers the equipment and procedures used for sampling pore-liquid from the vadose zone (unsaturated zone). The guide is limited to in situ techniques and does not include soil core collection and extraction methods for obtaining samples.
1.2 The term “pore-liquid” is applicable for liquids from aqueous pore-liquid to oil. However, the samplers described in this guide were designed, and are used to sample aqueous pore-liquids only. The abilities of these samplers to collect other pore-liquids may be quite different than those described.
1.3 Some of the samplers described in this guide are not currently commercially available. These samplers are presented because they may have been available in the past, and may be encountered at sites with established vadose zone monitoring programs. In addition, some of these designs are particularly suited to specific situations. If needed, these samplers could be fabricated.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.