Standard Test Method for Determination of Sulfuric Acid Mist in the Workplace Atmosphere (Ion Chromatographic) — 3 стр.
Область применения

1.1 This ion chromatographic test method describes the determination of sulfuric acid mist in air samples collected from workplace atmospheres in a three-piece cassette filter.

1.2 The lower detection limit of this test method is 0.017 mg/m of sulfuric acid (H2SO4) mist in 60 L of air sampled at 1 L/min.

1.3 This test method is relatively free from interference. The only known interference is soluble or partially soluble sulfate salts.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 9.

ICS
13.040.30 Workplace atmospheres / Атмосфера рабочей зоны
Сборник ASTM
11.07 Air Quality / Атмосферный анализ
Тематика
Atmospheric Analysis