Differential scanning calorimeters are used to determine chemical reaction thermal profiles of materials. One such reaction is the curing of thermosetting resins.
This test method is useful for both specification acceptance and for research.
Область применения1.1 This test method covers determination of curing parameters of pultrusions resins by differential scanning calorimetry.
1.2 This test method is applicable to pultrusion resin solutions with adequate initiator(s).
1.3 The normal operating temperature range is from 0 to 200°C.
Note 1—Resin systems that do not form an adequate baseline are not covered by this test method.
1.4 Computer or electronic based instruments or data treatment equivalent to this practice may also be used.
1.5 The values stated in SI units are to be regarded as standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Note 1.
Note 2—There is no known ISO equivalent to this test method.