ASTM D5627-94(2009)e1

Заменен
Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins — 3 стр.
Значение и использование

The presence of water extractables in ion-exchange resins can cause fouling of other materials downstream and contamination of process water. The quantity of water extractables is sometimes used as a specification to indicate resin quality, and typical values are 0.01 to 0.1 %.

It is recognized that this test method may not remove all potential sloughage products and does not measure volatile compounds. More extensive extraction and identification of compounds may be needed in specific cases.

Область применения

1.1 This test method covers the measurement of water soluble extractable residue from particulate ion-exchange resins based on elevated temperature extraction and gravimetric determination of residue.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
13.060.50 Examination of water for chemical substances / Исследование воды для определения содержания химических веществ
Сборник ASTM
11.02 Water (II) / Вода (II)
Тематика
Water Testing