ASTM D5785-95(2006)

Заменен
Standard Test Method for (Analytical Procedure) for Determining Transmissivity of Confined Nonleaky Aquifers by Underdamped Well Response to Instantaneous Change in Head (Slug Test) — 5 стр.
Значение и использование

The assumptions of the physical system are given as follows:

The aquifer is of uniform thickness and confined by impermeable beds above and below.

The aquifer is of constant homogeneous porosity and matrix compressibility and of homogeneous and isotropic hydraulic conductivity.

The origin of the cylindrical coordinate system is taken to be on the well-bore axis at the top of the aquifer.

The aquifer is fully screened.

The assumptions made in defining the momentum balance are as follows:

The average water velocity in the well is approximately constant over the well-bore section.

Flow is laminar and frictional head losses from flow across the well screen are negligible.

Flow through the well screen is uniformly distributed over the entire aquifer thickness.

Change in momentum from the water velocity changing from radial flow through the screen to vertical flow in the well are negligible.

The system response is an exponentially decaying sinusoidal function.

Область применения

1.1 This test method covers determination of transmissivity from the measurement of the damped oscillation about the equilibrium water level of a well-aquifer system to a sudden change of water level in a well. Underdamped response of water level in a well to a sudden change in water level is characterized by oscillatory fluctuation about the static water level with a decrease in the magnitude of fluctuation and recovery to initial water level. Underdamped response may occur in wells tapping highly transmissive confined aquifers and in deep wells having long water columns.

1.2 This analytical procedure is used in conjunction with the field procedure Test Method D4044 for collection of test data.

1.3 LimitationsSlug tests are considered to provide an estimate of transmissivity of a confined aquifer. This test method requires that the storage coefficient be known. Assumptions of this test method prescribe a fully penetrating well (a well open through the full thickness of the aquifer), but the slug test method is commonly conducted using a partially penetrating well. Such a practice may be acceptable for application under conditions in which the aquifer is stratified and horizontal hydraulic conductivity is much greater than vertical hydraulic conductivity. In such a case the test would be considered to be representative of the average hydraulic conductivity of the portion of the aquifer adjacent to the open interval of the well. The method assumes laminar flow and is applicable for a slug test in which the initial water-level displacement is less than 0.1 or 0.2 of the length of the static water column.

1.4 This test method of analysis presented here is derived by van der Kamp (1) based on an approximation of the underdamped response to that of an exponentially damped sinusoid. A more rigorous analysis of the response of wells to a sudden change in water level by Kipp (2) indicates that the method presented by van der Kamp (1) matches the solution of Kipp (2) when the damping parameter values are less than about 0.2 and time greater than that of the first peak of the oscillation (2).

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
93.160 Hydraulic construction / Сооружение гидротехнических объектов
Сборник ASTM
04.08 Soil and Rock (I): D420 – D5876 / Грунт и Горные породы (I): D420 – D5876