Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM D5812-96(2002)e1

Отменен
Standard Test Method for Determination of Organochlorine Pesticides in Water by Capillary Column Gas Chromatography (Withdrawn 2011) — 12 стр.
Причина отмены

Formerly under the jurisdiction of Committee D19 on Water, this Test Method was withdrawn in 2011 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Значение и использование

The extensive and widespread use of organochlorine pesticides and PCBs has resulted in their presence in all parts of the environment. These compounds are persistent and may have adverse effects on the environment. Thus, there is a need to identify and quantitate these compounds in water samples.

Область применения

1.1 This test method covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This test method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined. The tested compounds include the following:

PesticideChemical Abstract Service Registry Number Aldrin309-00-2-BHC319-84-6-BHC319-85-7-BHC319-86-8-BHC58-89-9-Chlordane5103-71-9-Chlordane5103-74-2Chlorobenzilate501-15-6Chloroneb2675-77-6Chlorothalonil2921-88-2DCPA1897-45-64,4`-DDD72-54-84,4`-DDE72-55-94,4`-DDT50-29-3Dieldrin60-57-1Endosulfan I959-98-8Endosulfan II33213-65-9Endosulfan sulfate1031-0708Endrin72-20-8Endrin aldehyde7421-93-4Etridiazole2593-15-9Heptachlor76-44-8Heptachlor epoxide1024-57-3Hexachlorobenzene118-74-1Methoxychlor72-43-5cis-Permethrin52645-53-1trans-Permethrin52645-53-1Propachlor1918-16-7Trifluralin1582-09-8 Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.

1.2 and list the applicable concentration ranges and precision and bias statements for this test method. The applicability of this test method to other compounds must be demonstrated.

1.3 The extract derived from this procedure may be analyzed for these constituents by using the gas chromatography (GC) conditions prescribed in Test Method D 5175 (capillary column). Although the columns used in this test method may be adequate for analyzing PCBs, no data were collected for any multi-congener constituents during methods development.

1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedures described in Section 12.

1.5 Analytes that are not separated chromatographically by either the primary or secondary chromatographic columns (for example, analytes having very similar retention times) cannot be identified and measured individually in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 7.9 and 13.4).

1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 9.

ICS
13.060.50 Examination of water for chemical substances / Исследование воды для определения содержания химических веществ
Сборник ASTM
11.02 Water (II) / Вода (II)
Тематика
Water Testing