4.1 GCLs must be properly manufactured in a manner consistent with a minimum level of quality control as determined by in-house testing of the final product. This practice suggests the types of tests, the methods of the testing and the minimum testing frequencies.
MD = machine direction
CD = cross-machine direction
Minimum = lowest result for the produced lot from which the supplied rolls were selected
Maximum = highest result for the produced lot from which the supplied rolls were selected
n/a = not applicable
4.2 It should be clearly recognized that manufacturers may perform additional tests or at greater frequency than required in this practice, or both. In this case, the manufacturer's quality control plan will then take precedence over this practice. The quoted tests and test methods in Table 1 must appear in the QC plan and the QC report.
4.3 It should also be recognized that purchasers and installers of GCLs may require additional tests or at a great frequency than called for in this practice, or both. The organization(s) producing such project specific specification or quality assurance plan should recognize that such requirements are beyond the current state of the practice. If such a request is made by purchasers or installers, they should clearly communicate the requirements to the manufacturer or supplier during the contract decisions in order that disputes do not arise at a subsequent time.
Область применения1.1 This practice covers the manufacturing quality control of geosynthetic clay liners (GCLs), describing types of tests, the proper test methods, and the minimum testing frequencies.
1.2 This practice is intended to aid manufacturers, suppliers, purchasers and users of GCLs in establishing a minimum level of effort for manufacturing quality control.
1.3 This practice does not address manufacturing quality assurance, product acceptance testing, or conformance testing. These are independent activities taken by organizations other than the GCL manufacturer.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.