This test method covered the determination of water content (or moisture content) in soil by the use of the electromagnetic technique called Time-Domain Reflectometry (TDR).
Formerly under the jurisdiction of Committee D18 on Soil and Rock, this test method was withdrawn in July 2014 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
Значение и использованиеThe determination of the water-content, or moisture content, of soil is one of the fundamental needs in the soil physics and hydrology disciplines. The need arises from requirements for defining the optimal time for irrigation, the infiltration rate, the soil-moisture flux, contaminant transport rates, and evaluating the potential for leakage from a waste site or a surface or subsurface barrier.
The TDR application covered in this test method is that used for point measurements of moisture content in soil. The application is either through manual insertion into the soil or by burying a probe in the subsurface to acquire moisture content data at a specific location. In addition, core samples may be tested with TDR at a drill site to acquire real-time soil moisture data.
Область применения1.1 This test method covers the determination of water content (or moisture content) in soil by the use of the electromagnetic technique called Time-Domain Reflectometry (TDR).
1.2 This test method was written to detail the procedure for conventional TDR measurements of soil. Other TDR applications exist for the purpose of quantifying water content in soil and are not covered here, such as flat probe technologies and wetting front advance methods.
1.3 Commercial TDR applications exist which automate the TDR methodology and are not detailed in this test method. It is likely that overlap exists in the automated commercial systems versus this applied method, and the user is encouraged to adhere to this test method when applicable.
1.4 This test method is one of a series on vadose zone characterization methods. Other standards have been prepared on vadose zone characterization techniques.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.