4.1 Although Test Method D4017 is widely used for the determination of water in paints and related materials, this method may overcome some of the variability found in the Karl Fischer method.
4.2 Control of water content is often important in controlling the performance of paints, and it is critical in determining volatile organic compound (VOC) content when VOC content is measured by difference from total volatile matter and water content as required in certain federal and state regulations.
Область применения1.1 This test method describes the determination of the total water content of paints using a calcium hydride reaction test kit, or water content between 2 % and 85 % water.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.