5.1 Greenhouse gases are reported to be a major contributor to global warming. Since “biomass CO2” emitted from combustion devices represents a net-zero carbon contribution to the atmosphere (that is, plants remove CO2 from the atmosphere and subsequent combustion returns it), it does not contribute additional CO2 to the atmosphere. The measurement of biomass (biogenic) CO2 allows regulators and stationary source owners/operators to determine the ratio of fossil-derived CO2 and biomass CO2 in developing control strategies and to meet federal, state, local and regional greenhouse gas reporting requirements.
5.2 The distinction of the two types of CO2 has financial, control and regulatory implications.
Область применения1.1 This practice defines specific procedures for the collection of gas samples from stationary emission sources for subsequent laboratory determination of the ratio of biomass (biogenic) carbon to total carbon (fossil derived carbon plus biomass or biogenic carbon) in accordance with Test Methods D6866.
1.2 This practice applies to stationary sources that burn municipal solid waste or a combination of fossil fuel (for example, coal, oil, natural gas) and biomass fuel (for example, wood, wood waste, paper, agricultural waste, biogas) in boilers, combustion turbines, incinerators, kilns, internal combustion engines and other combustion devices.
1.3 This practice applies to the collection of integrated samples over periods from 1 hour to 24 hours, or longer.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.