This test method provides a uniform procedure for radiographic examination of weldments using industrial radiographic film. Requirements expressed in this method are intended to control the quality of the radiographic images and are not intended for controlling acceptability or quality of welds. The apparatus shall comprise of a radiation source which may be X-ray or gamma-ray source; film holders and cassettes; intensifying screens such as lead-foil, fluorescent, fluorometallic, or other metallic screens; filters which shall be used whenever the contrast reductions caused by low energy, scattered radiation, or the extent of undercut (edge burn-off) occurring on production radiographs are of significant magnitude to cause difficulty in meeting the quality level or radiographic coverage requirements stipulated by the job order or contract; masking to improve radiographic quality; IQI's or penetrameters; shims, separate blocks, or like sections to facilitate IQI positioning; radiographic location and identification markers; and radiographic density measurement device. The test method shall meet the radiographic coverage, radiographic film quality, radiographic quality level, acceptance level, and radiographic density limitations. Procedures for surface preparation, radiation application and protection, IQI selection and placement, shim utilization, radiograph identification, and single-wall or double-wall radiographic techniques are addressed.
Область применения1.1 This test method provides a uniform procedure for radiographic examination of weldments using industrial radiographic film. Requirements expressed in this method are intended to control the quality of the radiographic images and are not intended for controlling acceptability or quality of welds.
1.2 The radiographic extent, the quality level, and the acceptance criteria to be applied shall be specified in the contract, purchase order, product specification, or drawings.
1.3 The radiographic techniques stated herein provide adequate assurance for defect detectability; however, it is recognized that, for special applications, specific techniques using more or less stringent requirements may be required than those specified. In these cases, the use of alternative radiographic techniques shall be as agreed upon between purchaser and supplier (also see Section ).
1.4 The values stated in inch-pound units are to be regarded as standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (For more specific safety precautionary information, see Section .)