ASTM E1039-99

Отменен
Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004) — 4 стр.
Причина отмены

This test method is intended to be used for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution defined by Tables E 892. The recommended physical requirements for these reference cells are described in Specification E 1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

Formerly under the jurisdiction of Committee E44 on Solar, Geothermal and Other Alternative Energy Sources, this test method was withdrawn in March 2004 because no laboratories currently use it, and because Test Method E 1125 is a more accurate test method.

For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard's Document Summary page on the ASTM website.

Область применения

1.1 This test method is intended to be used for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution defined by Tables E892. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

1.2 Primary global reference cells are calibrated outdoors in natural sunlight by reference to a pyranometer that is used to measure the global irradiance.

1.3 This test method applies only to the calibration of a photovoltaic cell which demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143.

1.4 This test method applies only to the calibration of single- or poly-crystalline silicon reference cells that have been fabricated with a single photovoltaic junction.

1.5 There is no similar or equivalent ISO standard.