Standard Classification for Serviceability of an Office Facility for Layout and Building Factors<rangeref></rangeref > — 15 стр.
Значение и использование

4.1 Each Facility Rating Scale (see Figs. 1-12) in this classification provides a means to estimate the level of serviceability of a building or facility for one topic of serviceability and to compare that level against the level of any other building or facility.

4.2 This classification can be used for comparing how well different buildings or facilities meet a particular requirement for serviceability. It is applicable despite differences such as location, structure, mechanical systems, age, and building shape.

4.3 This classification can be used to estimate the amount of variance of serviceability from target or from requirement, for a single office facility or within a group of office facilities.

4.4 This classification can be used to estimate the following:

4.4.1 Serviceability of an existing facility for uses other than its present use.

4.4.2 Serviceability (potential) of a facility that has been planned but not yet built.

4.4.3 Serviceability (potential) of a facility for which remodeling has been planned.

4.5 Use of this classification does not result in building evaluation or diagnosis. Building evaluation or diagnosis generally requires a special expertise in building engineering or technology and the use of instruments, tools, or measurements.

4.6 This classification applies only to facilities that are building constructions, or parts thereof. (While this classification may be useful in rating the serviceability of facilities that are not building constructions, such facilities are outside the scope of this classification.)

4.7 This classification is not intended for, and is not suitable for, use for regulatory purposes, nor for fire hazard assessment nor for fire risk assessment.

Область применения

1.1 This classification covers matched sets of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for layout and building factors.

1.2 Within that aspect of serviceability, each matched set of scales, shown in Figs. 1-12, are for classifying one topic of serviceability. Each topic is typically broken down into two or more demand functions or supply features. Each paragraph in an Occupant Requirement Scale (see Figs. 1-12) summarizes one level of serviceability on that function, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-12) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

FIG. 1 Demand Scale A.7.1.1 for Constraints on Layout

FIG. 2 Demand Scale A.7.1.2 for Constraints of Population Density

FIG. 3 Demand Scale A.7.1.3 for Cost of Upgrade

FIG. 4 Supply Scale A.7.1.1 for Constraints on Layout

FIG. 5 Supply Scale A.7.1.2 for Population Density Supported

FIG. 6 Supply Scale A.7.1.3 for Cost of Upgrade

FIG. 7 Demand Scale A.7.2.1 for Tolerance of Sound and Visual Conditions

FIG. 8 Demand Scale A.7.2.2 Avoiding Glare on Monitors

FIG. 9 Supply Scale A.7.2.1 Constraints on Layout

FIG. 10 Supply Scale A.7.2.2 Avoiding Glare on Monitors

FIG. 11 Demand Scale A.7.3 for Influence of Building Loss Features on Space Needs

FIG. 12 Supply Scale A.7.3 Influence of Building Loss Features on Space Needs

1.3 The entries in the Facility Rating Scale (see Figs. 1-12) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.

1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.

1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1679. The scales in this classification are complimentary to and compatible with Practice E1679. Each requires the other.

1.6 The scales are intended to identify the levels of various requirements unique to a particular user, and the serviceability (capability) of a building to meet those requirements. The scales thus supplement rather than include code requirements. It remain the responsibility of designers, builders, and building managers to meet applicable code requirements relative to their respective roles in facility design, construction, and ongoing management.

1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS
35.260 Office. Including typewriters, dictation equipment, addressing machines, letter opening machines, letter folding machines, postal franking machines, their ribbons and other accessories, etc. / Машины конторские. Включая пишущие машинки, диктофоны, адресные машины, машины для вскрывания писем, машины для складывания писем, почтовые франкировальные машины, ленты и другие приспособления к ним и т.д.
Сборник ASTM
04.11 Building Constructions (I): E72-E2110 / Строительство зданий (I): E72-E2110
Тематика
Buildings