Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM E177-26a

Действует
Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods — 9 стр.
Значение и использование

4.1 Precision and bias describe performance of a test method by summarizing random error and systematic error. They depend on the sample type and the testing situation that governs the sources of variability that apply.

4.2 Part A of the “Blue Book,” Form and Style for ASTM Standards, requires that all test methods include statements of precision and bias based on an interlaboratory test program. This practice describes and gives examples for the calculation of test precision and assessment of bias, and provides guidance for their use in statements about test methods.

4.2.1 Precision—A statement of precision allows potential users of a test method to assess in general terms the test method’s usefulness with respect to variability in proposed applications. A statement of precision is not intended to exhibit values that can be exactly duplicated in every user’s laboratory. Instead, the statement provides guidelines as to the magnitude of variability that can be expected between test results when the method is used in one, or in two or more, reasonably competent laboratories. For a discussion of precision, see 8.1.

4.2.2 Bias—A statement of bias furnishes guidelines on the relationship between a set of typical test results produced by the test method under specific test conditions and a related set of accepted reference values (see 9.1).

Реферат

The purpose of this practice is to present concepts necessary to the understanding of the terms “precision” and “bias” as used in quantitative test methods. This practice also describes methods of expressing precision and bias and, in a final section, gives examples of how statements on precision and bias may be written for ASTM test methods. A statement of precision allows potential users of a test method to assess in general terms the test method’s usefulness with respect to variability in proposed applications.

Область применения

1.1 The purpose of this practice is to present concepts necessary to the understanding of the terms “precision” and “bias” as used in quantitative test methods. This practice also describes methods of expressing precision and bias and, in a final section, gives examples of how statements on precision and bias may be written for ASTM test methods.

1.2 The system of units for this standard is not specified. Dimensional quantities in the standard are presented only as illustrations of calculation methods. The examples are not binding on products or test methods treated.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS
19.020 Test conditions and procedures in general / Условия и методика испытаний в целом
Сборник ASTM
14.01 Healthcare Informatics / Информатика в области здравоохранения