Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM E2164-01(2007)

Заменен
Standard Test Method for Directional Difference Test — 11 стр.
Значение и использование

The directional difference test determines with a given confidence level whether or not there is a perceivable difference in the intensity of a specified attribute between two samples, for example, when a change is made in an ingredient, a process, packaging, handling, or storage.

The directional difference test is inappropriate when evaluating products with sensory characteristics that are not easily specified, not commonly understood, or not known in advance. Other difference test methods such as the same-different test should be used.

A result of no significant difference in a specific attribute does not ensure that there are no differences between the two samples in other attributes or characteristics, nor does it indicate that the attribute is the same for both samples. It may merely indicate that the degree of difference is too low to be detected with the sensitivity (α, β, and Pmax) chosen for the test.

The method itself does not change whether the purpose of the test is to determine that two samples are perceivably different versus that the samples are not perceivably different. Only the selected values of Pmax, α, and β change. If the objective of the test is to determine if the two samples are perceivably different, then the value selected for α is typically smaller than the value selected for β. If the objective is to determine if no perceivable difference exists, then the value selected for β is typically smaller than the value selected for α and the value of Pmax needs to be stated explicitly.

Область применения

1.1 This test method covers a procedure for comparing two products using a two-alternative forced-choice task.

1.2 This method is sometimes referred to as a paired comparison test or as a 2-AFC (alternative forced choice) test.

1.3 A directional difference test determines whether a difference exists in the perceived intensity of a specified sensory attribute between two samples.

1.4 Directional difference testing is limited in its application to a specified sensory attribute and does not directly determine the magnitude of the difference for that specific attribute. Assessors must be able to recognize and understand the specified attribute. A lack of difference in the specified attribute does not imply that no overall difference exists.

1.5 This test method does not address preference.

1.6 A directional difference test is a simple task for assessors, and is used when sensory fatigue or carryover is a concern. The directional difference test does not exhibit the same level of fatigue, carryover, or adaptation as multiple sample tests such as triangle or duo-trio tests. For detail on comparisons among the various difference tests, see referencess. (1), (2), and (3).

1.7 The procedure of the test described in this document consists of presenting a single pair of samples to the assessors.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
19.020 Test conditions and procedures in general / Условия и методика испытаний в целом
Сборник ASTM
14.03 Sensory Evaluation; Temperature Measurement; Language Services and Products / Сенсорная оценка; Измерение температуры; Лингвистические услуги и продукты
Тематика
Sensory Evaluation