ASTM E2322-03(2009)

Заменен
Standard Test Method for Conducting Traverse and Concentrated Load Tests on Panels used in Floor and Roof Construction — 6 стр.
Значение и использование

Transverse LoadThe procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.

Concentrated LoadThis concentrated load test shall be used to evaluate surface indentation of structural framing members.

These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Test Method E 455. Impact loading shall be evaluated under Test Methods E 661 or E 695.

Область применения

1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions:

Section Test Specimens5 Loading6 Deformation Measurements7 Report9 Precision and Bias10 Testing Floors Transverse Load11 Concentrated Load12 Testing Roofs Transverse Load13 Concentrated Load14

1.2 This test method serves to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing or supporting members (floor joist, rafters, and trusses), or both.

1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

1.4 This standard is not intended to cover concrete floor slabs.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
91.060.30 Ceilings. Including screeds, ramps, etc. / Потолки. Полы. Лестницы. Включая маяки, пандусы и т.д.
Сборник ASTM
04.12 Building Constructions (II): E2112-latest; Sustainability; Asset Management; Technology and Underground Utilities / Строительство зданий (II): с E2112 и далее; Устойчивость; Система управления недвижимостью (системы эксплуатации зданий и сооружений); Технологии и Подземные коммуникации
Тематика
Buildings