Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM E2511-17

Заменен
Standard Guide for Detailing of EIFS-Clad Barrier and Drainage Wall Assemblies — 3 стр.
Значение и использование

4.1 This guide is for use by individuals and entities involved with the design and specification of EIFS details for a specific building.

4.2 This guide can be applied to both EIFS-clad barrier wall assembly and EIFS-clad wall with drainage.

4.3 This guide can be applied to new and existing EIFS buildings, prefabricated versus on-site installed EIFS, and residential and commercial EIFS buildings.

4.4 This guide is not meant to replace the types of information normally present in text format in a project’s specifications.

4.5 This guide is not applicable to EIFS materials used in non EIFS applications, such as a topcoat for other base materials like traditional Portland cement plaster (stucco) and concrete.

Область применения

1.1 This guide describes the types of project-specific construction conditions that need to be communicated by means of drawings (“details”) for the purpose of constructing Exterior Insulation and Finish System (EIFS)-clad barrier and drainage wall assemblies. EIFS manufacturers provide basic details for the installation of their materials and interface with adjacent materials. These details are generic and, in many cases, do not apply to specific project conditions.

1.2 This guide addresses only the EIFS itself and the interface between the EIFS and the materials immediately adjacent to the EIFS; it does not address all parts of the wall assembly.

1.3 Not all possible construction detail conditions are addressed by this guide. Identify and provide details for all construction conditions that exist on a specific building.

1.4 This guide is intended to supplement but not supersede information from the EIFS manufacturer about how their specific product should be detailed, nor to supersede technical product acceptance reports or the code requirements of regulatory authorities.

1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
91.060.10 Walls. Partitions. Façades / Стены. Перегородки. Фасады
Сборник ASTM
04.12 Building Constructions (II): E2112-latest; Sustainability; Asset Management; Technology and Underground Utilities / Строительство зданий (II): с E2112 и далее; Устойчивость; Система управления недвижимостью (системы эксплуатации зданий и сооружений); Технологии и Подземные коммуникации
Тематика
Buildings