ASTM E2939-13

Заменен
Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems — 4 стр.
Значение и использование

5.1 This practice can be used to determine an expected capacity for an existing or a proposed photovoltaic system in a particular location during a specified period of time (see data collection period in Test Method E2848).

5.2 The expected capacity calculated in accordance with this practice can be compared with the capacity measured according to Test Method E2848 when the RC are the same.

5.3 The comparison of expected capacity and measured capacity can be used as a criterion for plant acceptance.

5.4 The user of this practice must select the performance simulation period over which the reporting conditions and expected capacity will be derived. Seasonal variations will likely cause both of these to change with differing performance simulation periods.

5.5 When this practice is used in conjunction with Test Method E2848, the performance simulation period and the data collection period must agree. If they do not agree, the comparison between expected and measured capacity will not be meaningful.

5.6 Historical or measured5 plane-of-array irradiance, ambient air temperature and wind speed data can be used to select reporting conditions and calculate expected capacity. If historical data are used, the data collection period should match the time period of the measured data in terms of season and length.

5.7 The simulated power output that is used to calculate the expected capacity should be derived from a performance model designed to represent the photovoltaic system which will be reported per Test Method E2848.

Область применения

1.1 This practice provides procedures for determining the expected capacity of a specific photovoltaic system in a specific geographical location that is in operation under natural sunlight during a specified period of time. The expected capacity is intended for comparison with the measured capacity determined by Test Method E2848.

1.2 This practice is intended for use with Test Method E2848 as a procedure to select appropriate reporting conditions (RC), including solar irradiance in the plane of the modules, ambient temperature, and wind speed, needed for the photovoltaic system capacity measurement.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
27.160 Solar. Including photovoltaic energy systems / Гелиоэнергетика. Включая фотоэлектрические системы
Сборник ASTM
12.02 Nuclear (II), Solar, and Geothermal Energy; Radiation Processing / Ядерная энергия (II), Солнечная, и Геотермическая Энергия; Радиационная обработка
Тематика
Nuclear Technology