Standard Specification for Evaluating Accelerated Aging Performance of Electrochromic Devices in Sealed Insulating Glass Units — 3 стр.
Реферат

This specification applies to all electrochromic (EC) glass whose visible light transmittance or near infrared light transmittance properties, or both, can be changed reversibly by the application or removal of an electrical voltage. It covers absorptive and reflective EC devices in preassembled permanently sealed insulting glass units with one or more cavities in which at least one lite contains an EC device (which may be in the form of a laminated lite or a single pane with coatings applied). This specification is also valid for EC devices in preassembled insulating glass units with capillary tubes intentionally left open, but not for other types of dynamic glass which do not solely require an electrical stimulus to change light transmittance such as photochromic and thermochromic glazings and hybrid active/passive chromogenics. This specification is applicable only to sealed insulating glass units that are constructed with glass and fabricated for vision glass areas for use in buildings, such as sliding doors, windows, skylights, and exterior wall systems.

Область применения

1.1 This specification is applicable to all electrochromic (EC) glass whose visible light transmittance or near infrared light transmittance properties, or both, can be changed reversibly by the application or removal of an electrical voltage. This includes absorptive and reflective EC devices.

1.2 This specification does not apply to other types of dynamic glass which do not solely require an electrical stimulus to change light transmittance such as photochromic and thermochromic glazings and hybrid active/passive chromogenics.

1.3 This specification covers electrochromic devices in preassembled permanently sealed insulting glass units with one or more cavities in which at least one lite contains an EC device (which may be in the form of a laminated lite or a single pane with coatings applied). This specification is also applicable to EC devices in preassembled insulating glass units with capillary tubes intentionally left open. As such this specification also requires conformance to Specification E2190.

1.4 This specification is applicable only to sealed insulating glass units that are constructed with glass and fabricated for vision glass areas for use in buildings, such as sliding doors, windows, skylights, and exterior wall systems.

1.5 Qualification under this specification is intended to provide a basis for evaluating the aging performance of electrochromic devices in sealed insulating glass units.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS
81.040.20 Glass in building / Стекло для строительства зданий