4.1 These test methods for the chemical analysis of metals and alloys are primarily intended as referee methods to test such materials for compliance with composition specifications. It is assumed that all who use these methods will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.
Область применения1.1 These test methods cover the chemical analysis of copper alloys having chemical ranges within the following limits:2
Element
Composition, %
Aluminum
12.0 max
Antimony
1.0 max
Arsenic
1.0 max
Cadmium
1.5 max
Cobalt
1.0 max
Copper
40.0 min
Iron
6.0 max
Lead
27.0 max
Manganese
6.0 max
Nickel
50.0 max
Phosphorus
1.0 max
Silicon
5.0 max
Sulfur
0.1 max
Tin
20.0 max
Zinc
50.0 max
1.2 The test methods appear in the following sections:
Sections
Aluminum by the Carbamate Extraction-(Ethyl-
enedinitrilo) Tetraacetic Acid Disodium Salt (EDTA) Titrimetric Test Method [2 % to 12 %]
71 – 78
Copper by the Combined Electrodeposition Gravimetric and Oxalyldihydrazide Spectrophotometric Test Method [50 %, minimum]
10 – 18
Iron by the 1,10-Phenanthroline Spectrophotometric Test Method [0.003 % to 1.25 %]
19 – 28
Lead by Atomic Absorption Spectrometry [0.002 % to 15 %]
90 – 100
Lead by the (Ethylenedinitrilo) Tetraacetic Acid, Disodium Salt (EDTA) Titrimetric Test Method [2.0 % to 30.0 %]
29 – 36
Nickel by the Dimethylglyoxime Extraction Spectrophotometric Test Method [0.03 % to 5.0 %]
37 – 46
Nickel by the Dimethylglyoxime Gravimetric Test Method [4 % to 50 %]
55 – 62
Silver in Silver-Bearing Copper by Atomic Absorption Spectrometry [0.01 % to 0.12 %]
101 – 112
Tin by the Iodometric Titration Test Method [0.5 % to 20 %]
63 – 70
Tin by the Phenylfluorone Spectrophotometric Test Method [0.01 % to 1.0 %]
113 – 123
Zinc by Atomic Absorption Spectrometry [0.02 % to 2 %]
79 – 89
Zinc by the (Ethylenedinitrilo) Tetraacetic Acid Disodium Salt (EDTA) Titrimetric Test Method [2 % to 40 %]
47 – 54
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.