Каталог стандартов

+7 (495) 223-46-76 +7 (812) 309-78-59
inform@normdocs.ru

ASTM F1464-93(2005)

Отменен
Standard Specification for Oxygen Concentrators for Domiciliary Use (Withdrawn 2014) — 8 стр.
Причина отмены

Oxygen concentrators provide a safe source of oxygen-enriched air for patients in need. They are devices that raise the level of inspired oxygen by separating nitrogen or oxygen from ambient air.

Oxygen concentrators fall into two main classes according to the means whereby gas separation is effected, namely: oxygen concentrators in which oxygen selectively permeates or transports through a membrane or lattice, and pressure swing adsorbers (PSA) in which air is exposed at a certain pressure to molecular sieve material that selectively retains nitrogen and other components until they are subsequently released when the pressure is reduced.

The scope of this specification is not restricted to these two classes as alternative methods of concentrating oxygen may become available and it is not intended that this specification should restrict future developments.

Formerly under the jurisdiction of Committee F29 on Anesthetic and Respiratory Equipment, this specification was withdrawn in July 2014 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

Реферат

This specification covers requirements for oxygen concentrators. Oxygen concentrators provide a safe source of oxygen-enriched air for patients in need. They are devices that raise the level of inspired oxygen by separating nitrogen or oxygen from ambient air. Oxygen concentrators fall into two main classes according to the means whereby gas separation is effected, namely: oxygen concentrators in which oxygen selectively permeates or transports through a membrane or lattice, and pressure swing absorbers (PSA) in which air is exposed at a certain pressure to molecular sieve material that selectively retains nitrogen and other components until they are subsequently released when the pressure is reduced. Oxygen concentrators shall comply with the following requirements: protection against hazards from unwanted or excessive radiation; protection against excessive temperatures, and other safety hazards; accuracy of operating data and protection against hazardous output; and constructional requirements.

Область применения

1.1 This clause of the general standard applies except as follows (replacement): This particular specification specifies safety requirements for oxygen concentrators as defined in . This specification does not apply to oxygen concentrators intended to supply gas to several patients via a piped medical gas installation or to those intended for use in the presence of flammable anaesthetic or cleaning agents, or both.

1.2 The values stated in SI units are to be regarded as the standard.

ICS
11.040.10 Anaesthetic,. Including medical gas installations / Наркозные, дыхательные и реанимационные аппараты
Сборник ASTM
13.02 Medical and Surgical Materials and Devices (II): F2502–Latest; Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment / Медицинские и хирургические материалы и приборы (II): F2502-Latest; Скорая медицинская помощь; Поиск и Спасение; Оборудование для анестезии и искусственного дыхания
Тематика
Medical Services