Standard Test Method for Determining the Capacitance of a Membrane Switch — 2 стр.
Значение и использование

Capacitance testing is useful for design verification, quality control of materials, and workmanship.

High capacitance may interfere with the reliable performance of interface electronics.

Specific areas of testing are, but not limited to:

3.3.1 Conductor/dielectric/conductor crossing point,

3.3.2 Close proximity of conductors, and

3.3.3 Any other conductive surface such as shielding or metal backing panel.

Область применения

1.1 This test method covers the determination of capacitance(s) of a membrane switch.

ICS
29.120.40 Switches / Переключатели
Сборник ASTM
10.04 Electronics; Declarable Substances in Materials; 3D Imaging Systems; Additive Manufacturing Technologies / Электроника; Декларируемые вещества в материалах; Системы 3D-визуализации; Аддитивные технологии производства