Formerly under the jurisdiction of Committee F05 on Business Imaging Products, this practice was withdrawn in January 2020 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
Значение и использованиеThe image life of printed ink jet media in dark keeping conditions in typical office environments is pertinent to the end use of these materials. While natural aging is the most reliable method of assessing image stability, the length of time required makes this method impractical for most materials. As a result, accelerated tests often are used. This test practice is an accelerated short-term storage test that simulates long-term storage but at elevated temperatures. A room condition sample is also tracked to provide practical data. By measuring the time needed to obtain a predetermined color change at a variety of temperature conditions, the image life can be predicted using the Arrhenius method.
Note 2—The Arrhenius method is a predictive test based on mathematical extrapolation of high temperature tests to room temperature. In this test, long-term color changes are predicted by performing short-term tests at a series of high temperatures.
Since the ability of an ink jet print to withstand color changes is a function of temperature and humidity, it is important that dark stability be assessed under the conditions appropriate to the end use application. While ink jet prints may be handled and displayed under a variety of conditions, this test practice is intended to produce the color changes that may occur in ink jet prints upon dark keeping in typical office environments.
The accelerated procedure described in this test practice is intended to provide a means for predicting the life of an ink jet image under laboratory conditions. Test results are useful for specification acceptance between producer and user, for quality control, and for research and product development.
Область применения1.1 This practice describes an accelerated procedure intended to predict the lifetime of images stored in dark keeping conditions in typical office environments.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.